ExtremeXOS 12.1 Supported
Protocols
Switching
• RFC 3619 Ethernet Automatic Protection
Switching (EAPS) and EAPSv2
• IEEE 802.1D – 1998 Spanning Tree Protocol
(STP)
• IEEE 802.1D – 2004 Spanning Tree Protocol
(STP and RSTP)
• IEEE 802.1w – 2001 Rapid Reconfiguration for
STP, RSTP
• IEEE 802.1Q – 2003 (formerly IEEE 802.1s)
Multiple Instances of STP, MSTP
• EMISTP, Extreme Multiple Instances of
Spanning Tree Protocol
• PVST+, Per VLAN STP (802.1Q interoperable)
• Draft-ietf-bridge-rstpmib-03.txt – Definitions of
Managed Objects for Bridges with Rapid
Spanning Tree Protocol
• Extreme Standby Router Protocol (ESRP)
• IEEE 802.1Q – 1998 Virtual Bridged Local Area
Networks
• IEEE 802.3ad Static load sharing configuration
and LACP based dynamic configuration
• Software Redundant Ports
• IEEE 802.1AB – LLDP Link Layer Discovery
Protocol
• LLDP Media Endpoint Discovery (LLDP-MED),
ANSI/TIA-1057, draft 08
• Extreme Discovery Protocol (EDP)
• Extreme Loop Recovery Protocol (ELRP)
• Extreme Link State Monitoring (ELSM)
• IEEE 802.1ag L2 Ping and traceroute, Connectivity
Fault Management
Management and Traffic Analysis
• RFC 2030 SNTP, Simple Network Time Protocol
v4
• RFC 854 Telnet client and server
• RFC 783 TFTP Protocol (revision 2)
• RFC 951, 1542 BootP
• RFC 2131 BOOTP/DHCP relay agent and DHCP
server
• RFC 1591 DNS (client operation)
• RFC 1155 Structure of Mgmt Information
(SMIv1)
• RFC 1157 SNMPv1
• RFC 1212, RFC 1213, RFC 1215 MIB-II,
Ethernet-Like MIB & TRAPs
• RFC 1573 Evolution of Interface
• RFC 1650 Ethernet-Like MIB (update of RFC
1213 for SNMPv2)
• RFC 1901 – 1908 SNMP v2c, SMIv2 and
Revised MIB-II
• RFC 2570 – 2575 SNMPv3, user based
security, encryption and authentication
• RFC 2576 Coexistence between SNMP Version
1, Version 2 and Version 3
• RFC 1757 RMON 4 groups: Stats, History,
Alarms and Events
• RFC 2021 RMON2 (probe configuration)
• RFC 2925 Ping/Traceroute MIB
• RFC 2668 802.3 MAU MIB
• draft-ietf-hubmib-mau-mib-v3-02.txt
• RFC 1643 Ethernet MIB
• RFC 1493 Bridge MIB
• RFC 1354 IPv4 Forwarding Table MIB
• RFC 2737 Entity MIB v2
• RFC 2233 Interface MIB
• RFC 3621 PoE-MIB (PoE switches only)
• Secure Shell (SSH-2) client and server
• Secure Copy (SCP-2) client and server
• Secure FTP (SFTP) server
sFlow version 5
• Configuration logging
• Multiple Images, Multiple Configs
• RFC 3164 BSD Syslog Protocol with Multiple
Syslog Servers
––999 Local Messages (criticals stored across
reboots)
• Extreme Networks vendor MIBs (includes FDB,
PoE, CPU, Memory MIBs)
• XML APIs over Telnet/SSH and HTTP/HTTPS
• Web-based device management interface –
ExtremeXOS ScreenPlay
• Stacking – SummitStack (Summit products with
SummitStack feature only)
Security, Switch and Network Protection
• Secure Shell (SSH-2), Secure Copy (SCP-2) and
SFTP client/server with encryption/authentication
(requires export controlled encryption
module)
• SNMPv3 user based security, with encryption/
authentication (see above)
• RFC 1492 TACACS+
• RFC 2138 RADIUS Authentication
• RFC 2139 RADIUS Accounting
• RFC 3579 RADIUS EAP support for 802.1x
• RADIUS Per-command Authentication
• Access Profiles on All Routing Protocols
• Access Policies for Telnet/SSH-2/SCP-2
• Network Login – 802.1x, web and MAC-based
mechanisms
• IEEE 802.1x – 2001 Port-Based Network Access
Control for Network Login
• Multiple supplicants with multiple VLANs for
Network Login (all modes)
• Fallback to local authentication database (MAC
and Web-based methods)
• Guest VLAN for 802.1x
• RFC 1866 HTML – Used for web-based Network
Login and ScreenPlay
• SSL/TLS transport – used for web-based Network
Login and ExtremeXOS ScreenPlay, (requires
export controlled encryption module)
• MAC Security – Lockdown and Limit
• IP Security – RFC 3046 DHCP Option 82 with
port and VLAN ID
• IP Security – Trusted DHCP Server
• Layer 2/3/4 Access Control Lists (ACLs)
• RFC 2267 Network Ingress Filtering
• RPF (Unicast Reverse Path Forwarding) Control
via ACLs
• Wire-speed ACLs
• Rate Limiting / Shaping by ACLs
• IP Broadcast Forwarding Control
• ICMP and IP-Option Response Control
• SYN attack protection
• CPU DoS Protection with traffic rate-limiting to
management CPU
• Robust against common Network Attacks:
––CERT (http://www.cert.org)
––CA-2003-04: “SQL Slammer”
––CA-2002-36: “SSHredder”
––CA-2002-03: SNMP vulnerabilities
––CA-98-13: tcp-denial-of-service
––CA-98.01: smurf
––CA-97.28:Teardrop_Land -Teardrop and “LAND“
attack
––CA-96.26: ping
––CA-96.21: tcp_syn_flooding
––CA-96.01: UDP_service_denial
––CA-95.01: IP_Spoofing_Attacks_and_Hijacked_
Terminal_Connections
––IP Options Attack
• Host Attacks
––Teardrop, boink, opentear, jolt2, newtear,
nestea, syndrop, smurf, fraggle, papasmurf,
synk4, raped, winfreeze, ping –f, ping of death,
pepsi5, Latierra, Winnuke, Simping, Sping,
Ascend, Stream, Land, Octopus
Security, Router Protection – Requires Edge
License or above
• IP Security – DHCP enforcement via Disable
ARP Learning
• IP Security – Gratuitous ARP Protection
• IP Security – DHCP Secured ARP/ARP Validation
• Routing protocol MD5 authentication (see
above)
IPv4 Host Requirements
• RFC 1122 Host Requirements
• RFC 768 UDP
• RFC 791 IP
• RFC 792 ICMP
• RFC 793 TCP
• RFC 826 ARP
• RFC 894 IP over Ethernet
• RFC 1027 Proxy ARP
• RFC 2068 HTTP server
• IGMP v1/v2/v3 Snooping with Configurable
Router Registration Forwarding
• IGMP Filters
• Static IGMP Membership
• Multicast VLAN Registration (MVR)
IPv4 Router Requirements – Requires Edge
License or above
• RFC 1812 Requirements for IP Version 4
Routers
• RFC 1519 CIDR
• RFC 1256 IPv4 ICMP Router Discovery (IRDP)
• Static Unicast Routes
• Static Multicast Routes
• RFC 1058 RIP v1
• RFC 2453 RIP v2
• Static ECMP
• RFC 1112 IGMP v1
• RFC 2236 IGMP v2
• RFC 3376 IGMP v3
• RFC 1354 IP Forwarding Table MIB
• RFC 1724 RIPv2 MIB
IPv4 Router Requirements – Requires Advanced
Edge License or above
• RFC 2338 VRRP
• RFC 2787 VRRP MIB
• RFC 2328 OSPF v2 (Edge-mode)
• OSPF ECMP
• OSPF MD5 Authentication
• RFC 1587 OSPF NSSA Option
• RFC 1765 OSPF Database Overflow
• RFC 2370 OSPF Opaque LSA Option
• RFC 3623 OSPF Graceful Restart
• RFC 1850 OSPFv2 MIB
• RFC 2362 PIM-SM (Edge-mode)
• RFC 3569, draft-ietf-ssm-arch-06.txt PIM-SSM
PIM Source Specific Multicast
• draft-ietf-pim-mib-v2-o1.txt
IPv6 Host Requirements
• RFC 2460, Internet Protocol, Version 6 (IPv6)
Specification
• RFC 2461, Neighbor Discovery for IP Version 6,
(IPv6)
RFC 2463, Internet Control Message
Protocol (ICMPv6) for the IPv6 Specification
• RFC 2464, Transmission of IPv6 Packets
over Ethernet Networks
• RFC 2465, IPv6 MIB, General Group and
Textual Conventions
• RFC 2466, MIB for ICMPv6
• RFC 2462, IPv6 Stateless Address Auto
configuration – Host Requirements
• RFC 1981, Path MTU Discovery for IPv6,
August 1996 – Host requirements
• RFC 3513, Internet Protocol Version 6 (IPv6)
Addressing Architecture
• RFC 3587, Global Unicast Address Format
• Telnet server over IPv6 transport
• SSH-2 server over IPv6 transport
• Ping over IPv6 transport
• Traceroute over IPv6 transport
IPv6 Interworking and Migration
• RFC 2893, Configured Tunnels
• RFC 3056, 6to4
IPv6 Router Requirements – Requires Edge
License or above
• RFC 2462, IPv6 Stateless Address Auto
configuration – Router Requirements
• RFC 1981, Path MTU Discovery for IPv6,
August 1996 – Router requirements
• RFC 2710, IPv6 Multicast Listener Discovery
v1 (MLDv1) Protocol
• RFC 3810, IPv6 Multicast Listener Discovery
v2 (MLDv2) Protocol
• Static Unicast routes for IPv6
• RFC 2080, RIPng
• Static ECMP
Core Protocols for Layer 2, IPv4 and IPv6 –
Requires Core License or above
• EAPSv2 Shared Ports – multiple interconnections
between rings
• PIM-DM Draft IETF PIM Dense Mode
draft-ietf-idmr-pim-dm-05.txt, draft-ietf-pimdm-
new-v2-04.txt
• RFC 3618 Multicast Source Discovery
Protocol (MSDP)
• RFC 3446 Anycast RP using PIM and MSDP
• RFC 2740 OSPFv3, OSPF for IPv6
• RFC 1771 Border Gateway Protocol 4
• RFC 1965 Autonomous System Confederations
for BGP
• RFC 2796 BGP Route Reflection (supersedes
RFC 1966)
• RFC 1997 BGP Communities Attribute
• RFC 1745 BGP4/IDRP for IP-OSPF Interaction
• RFC 2385 TCP MD5 Authentication for BGPv4
• RFC 2439 BGP Route Flap Damping
• RFC 2918 Route Refresh Capability for BGP-4
• RFC 3392 Capabilities Advertisement with
BGP-4
• RFC 4360 BGP Extended Communities
Attribute
• RFC 4486 Subcodes for BGP Cease
Notification message
• draft-ietf-idr-restart-10.txt Graceful Restart
Mechanism for BGP
• RFC 4760 Multiprotocol extensions for BGP-4
• RFC 1657 BGP-4 MIB
• Draft-ietf-idr-bgp4-mibv2-02.txt – Enhanced
BGP-4 MIB
• RFC 1195 Use of OSI IS-IS for Routing in
TCP/IP and Dual Environments (TCP/IP
transport only)
• RFC 2763 Dynamic Hostname Exchange
Mechanism for IS-IS
• RFC 2966 Domain-wide Prefix Distribution
with Two-Level IS-IS
• RFC 2973 IS-IS Mesh Groups
• Draft-ietf-isis-restart-02 Restart Signaling for
IS-IS
• Draft-ietf-isis-ipv6-06 Routing IPv6 with IS-IS
• Draft-ietf-isis-wg-multi-topology-11 Multi
Topology (MT) Routing in IS-IS
QoS, VLAN Services and MPLS
Quality of Service and Policies
• IEEE 802.1D – 1998 (802.1p) Packet Priority
• RFC 2474 DiffServ Precedence, including 8
queues/port
• RFC 2598 DiffServ Expedited Forwarding (EF)
• RFC 2597 DiffServ Assured Forwarding (AF)
• RFC 2475 DiffServ Core and Edge Router
Functions
VLAN Services: VLANs, vMANs
• IEEE 802.1Q VLAN Tagging
• IEEE 802.1v: VLAN classification by Protocol
and Port
• Port-based VLANs
• Protocol-based VLANs
• MAC-based VLANs
• Multiple STP domains per VLAN
• Upstream Forwarding Only / Disable Flooding
• draft-sanjib-private-vlan-08.txt Private VLANs
• Asymmetric VLANs
• VLAN Translation
• IEEE 802.1ad Provider Bridge Network, virtual
MANs (vMANs)
• vMAN Ethertype Translation/Secondary VMAN
Ethertype
• VLAN Aggregation
Summit X250e-24t
General Specifications
Performance
• 48.8 Gbps switch fabric bandwidth
• 36.3 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per switch
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 24 ports 10/100BASE-T with auto-speed and
auto-polarity
• 2 ports Gigabit Ethernet (100/1000BASE-X
SFP, shared PHY with 2 10/100/1000BASE-T
ports)
• 2 SummtStack stacking interfaces
• 1 port Serial (control port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-160 with EPS-T
|
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 12.13 Inches/30.8 Cm
• Weight: 10.47 Lbs/4.76 Kg
Operating Specifications
Temperature
Power & Acoustic Sound
• Voltage Input Range: 90 – 264V Nominal
Input Ratings: 100 – 240V~, 50/60Hz, 1.0A
• Input Current: 0.5A @ 115V~ (lowline) 0.25A
@ 230V~ (high-line)
• Maximum In-Rush Current: 30A @115V, 60A
@ 230V
• Efficiency: 83% with 60% – 100% load
• Line Frequency Range: 47 – 63 Hz
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 36W (123 BTU/h)
• Power Consumption: 36W (123 BTU/h)
• Acoustic Noise (Low FAN Speed): 37 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 45 dBA per
ISO 7779
• MTBF: 300kHrs
Summit X250e-48t
General Specifications
Performance
• 97.6 Gbps switch fabric bandwidth
• 39.9 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per 24-port
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 48 ports 10/100BASE-T with auto-speed and
auto-polarity
• 2 ports Gigabit Ethernet (100/1000BASE-X
SFP, shared PHY with 2 10/100/1000BASE-T
ports)
• 2 SummitStack stacking interfaces
• 1 port serial (console port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-160 with EPS-T
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 15.28 Inches/38.8 Cm
• Weight: 12.06 lbs/5.48 Kg
Operating Specifications
Power & Acoustic Sound
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100-240V~, 50/60Hz,
1.0A
• Input Current: 0.6A @ 115V~ (lowline) 0.3A
@ 230V~ (high-line)
• Maximum In-Rush Current: 30A @115V, 60A
@ 230V
• Efficiency: 83% with 60% – 100% load
• Line Frequency Range: 47 – 63 Hz
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 51W (174 BTU/h)
• Power Consumption: 51W (174 BTU/h)
• Acoustic Noise (Low FAN Speed): 37 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 47 dBA per
ISO 7779
• MTBF: 300kHrs
Summit X250e-24x
General Specifications
Performance
• 48.8 Gbps switch fabric bandwidth
• 36.3 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per switch
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 24 ports 100BASE-X supporting 100BASE-X
SFP Optical Transceivers
• 2 ports Gigabit Ethernet (100/1000BASE-X
SFP, shared PHY with 2 10/100/1000BASE-T
ports)
• 2 SummitStack stacking interfaces
• 1 port Serial (control port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-160 and EPS-T
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 12.13 Inches/30.8 Cm
• Weight: 10.21 Lbs/4.64 Kg
Operating Specifications
Power & Acoustic Sound
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100 – 240V~,
50/60Hz, 1.0A
• Input Current: 1.0A @ 115V~ (lowline) 0.5A
@ 230V~ (high-line)
• Maximum In-Rush Current: 30A @ 115V, 60A
@ 230V
• Efficiency: 83% with 60% – 100% load
• Line Frequency Range: 47 – 63 Hz
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 49W (167.2 BTU/h)
• Power Consumption: 49W (167.2 BTU/h)
• Acoustic Noise (Low FAN Speed): 37 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 45 dBA per
ISO 7779
• MTBF: 300kHrs
Summit X250e-24p
General Specifications
Performance
• 48.8 Gbps switch fabric bandwidth
• 36.3 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per switch
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 24 ports 10/100BASE-T PoE with auto-speed
and auto-polarity
• 2 ports Gigabit Ethernet (100/1000BASE-X
SFP, shared PHY with 2 10/100/1000BASE-T
ports)
• 2 SummitStack stacking interfaces
• 1 port serial (console port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-500
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 12.13 Inches/30.8 Cm
• Weight: 12.1 Lbs/5.46 Kg
Operating Specifications
Power & Acoustic Sound
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100 – 240V~,
50/60Hz, 5.5A
• Input Current (with PoE full load): 4.4A @
115V~ (lowline) 2.2A @ 230V~ (high-line)
• Input Current (without PoE): 0.75A @ 115V~
(lowline) 0.5A @ 230V~ (high-line)
• Maximum In-Rush Current: 30A @115V, 60A
@230V
• Efficiency: 81% with 60% – 100% load
• Line Frequency Range: 47 – 63 Hz
• Nominal Frequency Range: 50 – 60 Hz
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation (with PoE full load): 100W
(341 BTU/h)
• Power Consumption (with PoE full load):
470W (1604 BTU/h)
• Heat Dissipation (without PoE): 55W (188
BTU/h)
• Power Consumption (without PoE): 55W (188
BTU/h)
• Acoustic Noise (Low FAN Speed): 39 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 44 dBA per
ISO 7779
• MTBF: 300kHrs
Summit X250e-48p
General Specifications
Performance
• 97.6 Gbps switch fabric bandwidth
• 39.9 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per 24-port
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 48 ports 10/100BASE-T PoE with auto-speed
and auto-polarity
• 2 ports Gigabit Ethernet (SFP mini-GBIC,
shared PHY with 2 10/100/1000BASE-T
ports)
• 2 SummitStack stacking interfaces
• 1 port serial (console port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-C with EPS-600LS
• External Power Supply–EPS-C Chassis
accepts up to three EPS-600LS power
modules and provides the following capability
depending upon the number of EPS 600LS
installed
––One EPS-600LS
• Redundant, up to 370W PoE power
––Two EPS-600LS
• Redundant, up to 370W PoE power
• Non-Redundant, up to 740W PoE power
––Three EPS-600LS
• Redundant, up to 740W PoE power
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 15.28 Inches/38.8 Cm
• Weight: 12.06 lbs/5.48 Kg
Operating Specifications
Power & Acoustic Sound
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100 – 240V~,
50/60Hz, 5.5A
• Input Current (with PoE full load): 4.5A @
115V~ (lowline) 2.25A @ 230V~ (highline)
• Input Current (without PoE): 0.75A @ 115V~
(lowline) 0.5A @ 230V~ (highline)
• Maximum In-Rush Current: 30A @ 115V, 60A
@ 230V
• Efficiency: 78% with 60% – 100% load
• Line Frequency Range: 47 – 63 Hz
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation (with PoE full load): 130W
(444 BTU/h)
• Power Consumption (with PoE full load):
525W (1,791 BTU/h)
• Heat Dissipation (without PoE): 75W (256
BTU/h)
• Power Consumption (without PoE): 75W (256
BTU/h)
• Acoustic Noise (Low FAN Speed): 39 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 46 dBA per
ISO 7779
• MTBF: 300kHrs
Summit X250e-24tDC
General Specifications
Performance
• 48.8 Gbps switch fabric bandwidth
• 36.3 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per switch
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 24 ports 10/100BASE-T with auto-speed and
auto-polarity
• 2 ports Gigabit Ethernet (100/1000BASE-X
SFP, shared PHY with
2 10/100/1000BASE-T ports)
• 2 SummtStack stacking interfaces
• 1 port Serial (control port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-150DC with EPS-T2
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 12.13 Inches/30.8 Cm
• Weight: 9.88 Lbs/ 4.49 Kg
|
Operating Specifications
Power & Acoustic Sound
• Voltage Input Range: -40 to -72VDC
• Input Current Rating: 2.0A at -48VDC
• Input Current: 0.8A @ -40VDC, 0.5A @
-72VDC
• Maximum In-Rush Current: 20A @ -48VDC,
30A @ -72VDC
• Efficiency:78%
• Power Supply Input Socket: TYCO 206061-1
• Power Cord Input Plug: TYCO 206060-1
• Heat Dissipation: 31W (105.8 BTU/h)
• Power Consumption: 31W (105.8 BTU/h)
• Acoustic Noise (Low FAN Speed): 37 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 45 dBA per
ISO 7779
• MTBF: 300kHrs
Summit X250e-48tDC
General Specifications
Performance
• 97.6 Gbps switch fabric bandwidth
• 39.9 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per 24-port
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 48 ports 10/100BASE-T with auto-speed and
auto-polarity
• 2 ports Gigabit Ethernet (100/1000BASE-X
SFP, shared PHY with 2
10/100/1000BASE-T ports)
• 2 SummitStack stacking interfaces
• 1 port serial (console port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-150DC with EPS-T2
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 15.28 Inches/38.8 Cm
• Weight: 12.14 Lbs/ 5.52 Kg
Operating Specifications
Power & Acoustic Sound
• Voltage Input Range: -40 to -72VDC
• Input Current Rating: 2.0A at -48VDC
• Input Current: 1.25A @ -40VDC, 0.75A @
-72VDC
• Maximum In-Rush Current: 20A @ -48VDC,
30A@-72VDC
• Efficiency: 78%
• Power Supply Input Socket: TYCO 206061-1
• Power Cord Input Plug: TYCO 206060-1
• Heat Dissipation: 47W (160.4 BTU/h)
• Power Consumption: 47W (160.4 BTU/h)
• Acoustic Noise (Low FAN Speed): 37 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 47 dBA per
ISO 7779
• MTBF: 300kHrs
Summit X250e-24xDC
General Specifications
Performance
• 48.8 Gbps switch fabric bandwidth
• 36.3 Mpps frame forwarding rate
• 9,216 Byte maximum packet size (Jumbo
Frame)
• 128 load sharing trunks, up to 8 members
per trunk
• 8 QoS queues/port
• 4,094 VLANs (Port, Protocol, IEEE 802.1Q)
• 1,024 centralized ACL rules per switch
Forwarding Tables
• Layer 2/MAC Addresses: 8K
• IPv4 LPM Entries: 512
• IPv6 LPM Entries: 256
Rate Limiting
• Ingress bandwidth policing/rate limiting per
flow
• Egress bandwidth rate limiting per egress
queue
• Rate Limiting Granularity: 64Kbps
• Available Rate Limiters: 1,024 per switch
Indicators
• Per port status LED
• System Status LEDs: management, fan and
Power
Ports
• 24 ports 100BASE-X supporting 100BASE-X
SFP Optical Transceivers
• 2 ports Gigabit Ethernet (100/1000BASE-X
SFP, shared PHY with 2 10/100/1000BASET
ports)
• 2 SummitStack stacking interfaces
• 1 port Serial (control port)
• 1 10/100BASE-T out-of-band management
port
External Power Supply Support
• EPS-150DC with EPS-T2
Physical Specifications
Dimensions and Weight
• Height: 1.73 Inches/4.4 Cm
• Width: 17.35 Inches/44.1 Cm
• Depth: 12.13 Inches/30.8 Cm
• Weight: 9.97 Lbs/ 4.53 Kg
Operating Specifications
Power & Acoustic Sound
• Voltage Input Range: -40 to -72VDC
• Input Current Rating: 2.0A at -48VDC
• Input Current: 1.25A @ -40VDC, 0.75A @
-72VDC
• Maximum In-Rush Current: 20A@-48VDC,
30A@-72VDC
• Efficiency: 83%
• Power Supply Input Socket: TYCO 206061-1
• Power Cord Input Plug: TYCO 206060-1
• Heat Dissipation: 42W (143.3 BTU/h)
• Power Consumption: 47W (160.4 BTU/h)
• Acoustic Noise (Low FAN Speed): 37 dBA per
ISO 7779
• Acoustic Noise (High FAN Speed): 47 dBA per
ISO 7779
• MTBF: 300kHrs
All Summit X250e Series
Regulatory/Safety Standards
North American Safety of ITE
• 9UL 60950-1:2003 1st Ed., Listed Device
(U.S.)
• CSA 22.2#60950-1-03 1st Ed. (Canada)
• Complies with FCC 21CFR 1040.10 (U.S.
Laser Safety)
• CDRH Letter of Approval (U.S. FDA Approval)
• IEEE 802.3af 6-2003 Environment A for PoE
Applications
European Safety of ITE
• EN 60950-1+A11:2001 TUV-R GS Mark by
German Notified Body
• EN 60825-1+A2:2001 (Lasers Safety)
• 73/23/EEC Low Voltage Directive
International Safety of ITE
• CB Report & Certificate per IEC 60950-
1:2001+All Country Deviations
• AS/NZS 60950-1 (Australia /New Zealand)
EMI/EMC Standards
• North America EMC for ITE
• FCC CFR 47 part 15 Class A (U.S.A.)
• ICES-003 Class A (Canada)
• European EMC standards
• EN 55022+A2:2003 Class A
• EN 55024+A2:2003 Class A includes IEC
61000-4- 2, 3, 4, 5, 6, 11
• EN 61000-3-2,3 (Harmonics & Flicker)
• ETSI EN 300 386:2001 (EMC Telecommunications)
• 89/336/EEC EMC Directive
International EMC Certifications
• CISPR 22:1997 Class A (International
Emissions)
• CISPR 24:1997 Class A (International
Immunity)
• IEC/EN 61000-4-2 Electrostatic Discharge,
8kV Contact, 15kV Air, Criteria A
• IEC/EN 61000-4-3 Radiated Immunity
10V/m, Criteria A
• IEC/EN 61000-4-4 Transient Burst, 1kV,
Criteria A
• IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G,
Level 3, Criteria A
• IEC/EN 61000-4-6 Conducted Immunity,
0.15- 80MHz, 10V/m unmod. RMS, Criteria A
• IEC/EN 61000-4-11 Power Dips & Interruptions,
>30%, 25 periods, Criteria C
Country Specific
• VCCI Class A (Japan Emissions)
• AS/NZS 3548 ACA (Australia Emissions)
• CNS 13438:1997 Class A (BSMI-Taiwan)
• MIC Mark, EMC Approval (Korea)
Telecom Standards
• ETSI EN 300 386:2001 (EMC Telecommunications)
• ETSI EN 300 019 (Environmental for
Telecommunications)
• Metro Ethernet Forum (MEF) 9 and 14
certification
IEEE 802.3 Media Access Standards
• IEEE 802.3 10BASE-T
• IEEE 802.3u 100BASE-TX
• IEEE 802.3ab 1000BASE-T
• IEEE 802.3z 1000BASE-X
Environmental Standards
• EN/ETSI 300 019-2-1 v2.1.2 – Class 1.2
Storage
• EN/ETSI 300 019-2-2 v2.1.2 – Class 2.3
Transportation
• EN/ETSI 300 019-2-3 v2.2.2 – Class 3.1e
Operational
• EN/ETSI 300 753 (1997-10) – Acoustic
Noise ASTM D3580 Random Vibration
Unpackaged 1.5G
Operating Specifications
Temperature
• Operating Temperature Range: 0° C to 40° C
(32° F to 104° F)
• Operating Humidity: 10% to 93% relative
humidity, non-condensing
• Operational Shock (Half Sine): 30 m/s2 (3g),
11ms, 60 Shocks
• Operational Random Vibration: 5 – 500 Hz @
1.5g rms
Storage & Transportation Conditions
(Packaged)
• Transportation Temperature: -40° C to 70° C
(- 40° F to 158° F)
• Storage and Transportation Humidity: 60% to
95% RH, non-condensing
• Packaged Shock (Half Sine): 180 m/s2 (18g),
6ms, 600 shocks
• Packaged Sine Vibration: 5 – 62 Hz @ Velocity
5mm/s, 62 – 500 Hz @ 0.2 G
• Packaged Random Vibration: 5 – 20 Hz @ 1.0
ASD w/-3dB/oct. from 20 – 200 Hz
• 14 drops min on sides & corners @
42”(<15kg box)
Warranty
• Ltd Lifetime with Advanced Hardware
Replacement
• 90-days on Software
Power Supply Units
EPS-160/EPS-T
Dimensions and Weight
EPS-160
• Height: 1.69 Inches/4.3 Cm
• Width: 7.68 Inches/19.5 Cm
• Depth: 7.32 Inches/18.6 Cm
• Weight: 2.90 Lbs/1.32 Kg
EPS-T
• Height: 1.73 Inches/4.4 Cm
• Width: 17.32 Inches/44.0 Cm
• Depth: 7.64 Inches/19.4 Cm
• Weight: 3.74 Lbs/1.70 Kg
Power – EPS-160
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100 – 240V~,
50 – 60Hz, 10A
• Line Frequency Range: 47 – 63 Hz
• Maximum Input Current: 2A at 115 VAC, 1A
at 230 VAC
• Maximum Inrush Current: 30A at 115 VAC,
60A at 230 VAC
• Power Supply Input Socket: IEC 320 C144
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 38.5W (131.4 BTU/h)
• Power Consumption: 178W (607.4 BTU/h)
EPS-500
Dimensions and Weight
EPS-500
• Height: 1.73 Inches/4.4 Cm
• Width: 17.4 Inches/44 Cm
• Depth: 7.6 Inches/19.3 Cm
• Weight: 10.8 Lbs/4.9 Kg
Power
• Voltage Input Range: 90 – 264V
• Nominal Input Ratings: 100 – 240V~,
50 – 60Hz, 10A
• Line Frequency Range: 47 – 63 Hz
• Maximum Input Current: 5.75A at 115 VAC,
2.80A at 230 VAC
• Maximum Inrush Current: 30A at 115 VAC,
60A at 230 VAC
• Output: -50 VDC, 7.5A max, 375 Watts 12
VDC, 7.5A max, 90 Watts
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 158W (539.1 BTU/h)
• Power Consumption: 659W (2448.6 BTU/h)
EPS-C/EPS-600LS
Dimensions and Weight
EPS-C
• Height: 1.73 Inches/4.4 Cm
• Width: 17.32 Inches/44.0 Cm
• Depth: 11.81 Inches/30.0 Cm
• Weight: 7.17 Lbs/3.16 Kg
EPS-600LS
• Height: 1.69 Inches/4.3 Cm
• Width: 4.61 Inches/11.7 Cm
• Depth: 11.81 Inches/30.9 Cm
• Weight: 3.74 Lbs/1.70 Kg
Power – EPS-600LS
• Voltage Input Range: 90 – 264 V
• Nominal Input Voltage/Hz: 115V~/60Hz &
230V~/50Hz, 10.0A
• Line Frequency Range: 47 – 63 Hz
• Maximum Input Current Rating: 7.0A at 115
VAC, 3.5A at 230 VAC
• Maximum Inrush Current: 30A at 115 VAC,
60A at 230 VAC
• Power Supply Input Socket: IEC 320 C14
• Power Cord Input Plug: IEC 320 C13
• Heat Dissipation: 219W (747.7BTU/h)
• Power Consumption: 801W (2733.1BTU/h)
External Power Supply Chassis System –
EPS-C with three EPS-600LS installed
• Heat Dissipation: 360W (1228.4BTU/h)
• Power Consumption: 1620W (5,527.7BTU/h)
EPS-150DC/EPS-T2
Dimensions and Weight
EPS-150DC
• Height: 1.65 Inches/4.2 cm
• Width: 3.74 Inches/9.5 cm
• Depth: 10.12 Inches/25.7 cm
• Weight: 3.76 Lbs/1.71 Kg
EPS-T2
• Height: 1.77 Inches/4.5 cm
• Width: 17.32 Inches/44.0 cm
• Depth: 8.66 Inches/22.0 cm
• Weight: 4.0 Lbs/1.82 Kg
Power – EPS-150DC
• Voltage Input Range: -36 to -72VDC, 6.0A
• Input Current Rating: 5.5A @ -36VDC, 2.6A @
-72VDC
• Maximum Inrush Current: 20A@-48VDC, 40A
@ -72VDC
• Efficiency: 75% with 100% load at 25° C
• Power Supply Input Socket: TYCO 206061-1
• Power Cord Input Plug: TYCO 206060-1
• Heat Dissipation: 45W (153.5 BTU/h)
• Power Consumption: 195W (665.4 BTU/h)
|